Home | Industrial Ventilation Products | Heaters & Accessories | Duct Heater | Gas-Fired Duct Furnaces
Commercial Gas-Fired Duct Furnaces
Adding a gas-fired duct furnace to a new air handler or makeup air unit, or replacing a failed one? We handle both.
We match the duct furnace to your CFM, temperature rise, vent route and cooling coil layout.
We select the model, quote it, and return a selection ready for submittal.
Our offices are in Houston and Dallas-Fort Worth, serving Texas and the Gulf Coast, and we ship nationwide.
Not sure which duct furnace fits your air handler?
We match the duct furnace to your CFM, temperature rise and venting.
Key Takeaways
Gas-Fired Duct Furnace Types and Capacities
Gas-fired duct furnaces come in seven sizes from 100,000 to 400,000 BTU/hr, for natural gas or propane.
| Type | Input | Temperature rise | Venting | Best for |
|---|---|---|---|---|
| Power vented, bottom burner access | 100,000 to 400,000 BTU/hr | 30 to 80°F | Power vented, through the wall | Units hung high, serviced from below |
| Power vented, side burner access | 100,000 to 400,000 BTU/hr | 30 to 80°F | Power vented, through the wall | Tandem pairs on larger air handlers |
| Tubular heat exchanger | 100,000 to 400,000 BTU/hr | 30 to 100°F | Category III, vertical or horizontal | Higher temperature rise, 10-year heat exchanger warranty |
| Tubular, separated combustion | 100,000 to 400,000 BTU/hr | 30 to 100°F | Outside air for combustion | Dusty, humid or mildly corrosive spaces |
Common Questions
What is the difference between a duct furnace and a unit heater?
A duct furnace has no fan of its own and heats air that a separate blower moves through ductwork, such as an air handler or makeup air unit, against up to 2.0 inches of water column. A unit heater carries its own fan and blows heat straight into the room where the unit hangs.
Should I use a gas duct furnace or an electric duct heater?
A gas-fired duct furnace fits buildings with natural gas or propane service and loads of 100,000 to 400,000 BTU/hr per unit, at 80 to 82% thermal efficiency. An electric duct heater fits buildings without gas, small zone loads, and hazardous locations when built explosion-proof, and needs no flue, vent pipe or gas line.
Can a gas duct furnace go downstream of a cooling coil?
A gas-fired duct furnace is certified for installation upstream or downstream of a cooling coil. Downstream, moisture from the coil reaches the heat exchanger during the cooling season, so the manufacturer recommends 409 or 321 stainless steel over the standard 20-gauge aluminized steel. Order the stainless heat exchanger at purchase, since it is factory installed.
How much airflow does a 250,000 BTU duct furnace need?
A 250,000 BTU/hr power vented duct furnace delivers 200,000 BTU/hr of output and needs 2,315 CFM at an 80°F temperature rise, or 6,173 CFM at a 30°F rise. Higher airflow gives a lower rise. A 250,000 BTU/hr tubular duct furnace needs 1,896 CFM at a 100°F rise, or 6,321 CFM at a 30°F rise.
Choosing a Gas-Fired Duct Furnace
Choosing a gas-fired duct furnace comes down to temperature rise, venting and heat exchanger material. The furnace mounts in the supply duct of an air handling unit or makeup air unit.
Hazardous classified areas need explosion-proof duct heaters instead of a gas duct furnace.
Duct Furnace Temperature Rise Runs 30 to 100°F
- Power vented duct furnaces: 30 to 80°F rise.
- Tubular duct furnaces: 30 to 100°F rise, for makeup air that must lift cold outdoor air further.
- Pressure drop: 0.75 to 0.90 inches of water column at maximum airflow on power vented units. Size the blower for it.
Duct Furnace Venting Options for Every Mechanical Room
- Power vented: single wall pipe out a side wall, no roof opening.
- Category III tubular: vertical or horizontal, single or double wall pipe.
- Separated combustion: a tubular unit with an air inlet kit draws combustion air from outside, for dusty, humid or mildly corrosive spaces.
Duct Furnace Heat Exchangers Come in Aluminized or Stainless Steel
- Standard: 20-gauge aluminized steel.
- Stainless option: 409 on every type, 321 on power vented units, for entering air below 40°F, placement after a cooling coil, or mildly corrosive air.
- Warranty: 10 years on the tubular heat exchanger, flue collector and burners. One year limited on power vented units.
Related Heating and Air Equipment
- Electric duct heatersFor buildings without gas service or small zone loads
- Unit heatersCeiling-hung heat for open spaces with no ductwork
- Door heatersWarm air at dock doors and overhead doors
- Fin tube radiationPerimeter heat under windows and along outside walls
- Industrial heatersElectric, gas and explosion-proof heaters for industrial buildings
- Commercial kitchen ventilationHoods, exhaust fans and tempered makeup air for kitchens
- High-rise multifamily HVACCorridor makeup air and ventilation for apartment towers
- Oil and gas HVACHeating and ventilation for process sites and control rooms